Question:
What is the correct Clock setting for STK200?
Answer:
The best clock setting in Clock Fuses is External Crystal 3-12MHz (1111). The factory default is Internal Resonator. External clock (0000) only works on some AVR devices due to differences in the internal circuitry of different AVR microcontrollers